| Q_2+BSNE_RRSF1 | 32 | Limit on a single plant | System Strength | Limit Ross River SF to 80%, 60%, 40%, 20% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition |
| Q_2+1_R3_RRSF1 | 28 | Limit on a single plant | System Strength | Limit Ross River SF to100%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition |
| Q_2+LCCP_RRSF1 | 26 | Limit on a single plant | System Strength | Limit Ross River SF to 100%, 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition |
| Q_A39B_RRSF1 | 23 | Limit on a single plant | System Strength | Limit Ross River SF to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition |
| Q_A39_RRSF1 | 19 | Limit on a single plant | System Strength | Limit Ross River SF to 80%, 60%, 40%, 20% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition |
| Q_2+1_R4_RRSF1 | 19 | Limit on a single plant | System Strength | Limit Ross River SF to100%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition |
| NC_Q_RRSF1 | 7 | Limit on a single plant | Non-Conformance | Non Conformance Constraint for ROSSRIVER SOLAR FARM |
| Q_2+1_R2_RRSF1 | 6 | Limit on a single plant | System Strength | Limit Ross River SF to100%,80%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition |
| Q_2+3+VC_RRSF1 | 3 | Limit on a single plant | System Strength | Limit Ross River SF to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition |
| Q_A39C_RRSF1 | 0 | Limit on a single plant | System Strength | Limit Ross River SF to 80%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition |
| Q_STR_NIL_RRSF1 | 0 | Limit on a single plant | System Strength | Limit Ross River SF to 100%, 70%, 60% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville/Clarke Creek Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition |
| Q_2+RSVC_RRSF1 | 0 | Limit on a single plant | System Strength | Limit Ross River SF to 100%, 80%, 60%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition |
| Q_RRSF1_ZERO | 0 | Limit on a single plant | Unit Zero | Ross River solar farm upper limit of 0 MW |
| Q_A19A_RRSF1 | 0 | Limit on a single plant | System Strength | Limit Ross River SF to 80%, 40%, 0% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition |