| N^^N_6CGH_WGLT | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 182 | discharge | Out=Nil, limit Wagga to Lower Tumut (51) 330kV line flow to avoid voltage collapse post contingency trip of line 51, Feedback |
| N^^N_NIL_WGLT | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 178 | discharge | Out=Nil, limit Wagga to Lower Tumut (051) 330kV line flow to avoid voltage collapse post contingency trip of line 51, Feedback |
| N::N_CNCW_2 | Snowy to NSW: transient stability limits (Yass–Bannaby–Marulan) | 145 | discharge | Out = Canberra-Capital (6) line, stability limit (Snowy-NSW) for critical fault of one 330kV line between Yass and Bannaby/Marulan |
| N>NIL_999_9GL | Cowra to Bango (999) | 128 | discharge | Out= Nil, avoid O/L Cowra to Bango (999) 132kV line on trip of Bango to Yass (9GL) 132kV line, Feedback |
| N::N_SDUT_2 | Snowy to NSW: transient stability limits (Yass–Bannaby–Marulan) | 111 | discharge | Out = Upper Tumut-Stockdill (1) 330kV line, stability limit (Snowy-NSW) for fault of various location between Yass-South Morang area |
| N^^N_NIL_LTWG | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 66 | charge | Out=Nil, limit Lower Tumut to Wagga 330kV line flow to avoid voltage collapse post contingency trip of line 51, Feedback |
| N>YSTX_TX_NIL_LV | Snowy to NSW: transient stability limits (Yass–Bannaby–Marulan) | 36 | discharge | Out= One Yass 330/132kV TX, avoid O/L other Yass 132/330kV transformer on trip of Nil, Feedback |
| N>79_998_72 | Central-west NSW: Molong–Orange North 132 kV | 7 | discharge | Out= Stubbo to Uungula (79) or Uungula to Wellington (7J) 330kV line, avoid O/L on Cowra to Forbes North (998) on trip of Mt Piper to Wellington line (72), Feedback |
| N>7M_998_72 | Central-west NSW: Molong–Orange North 132 kV | 5 | discharge | Out= Stubbo to Wollar West (7M) 330kV line, avoid O/L on Cowra to Forbes North (998) on trip of Mt Piper to Wellington line (72), Feedback |
| N>NIL_YSTX_LV | Snowy to NSW: transient stability limits (Yass–Bannaby–Marulan) | 5 | discharge | Out= Nil, avoid O/L Either of Yass 132/330 Transformers on trip of Nil, Feedback |
| N::N_GRRP_2 | Snowy to NSW: transient stability limits (Yass–Bannaby–Marulan) | 4 | discharge | Out = Gullen Range to Rye Park (3P), stability limit (Snowy-NSW) for loss of Yass-Marulan (4/5) 330kV line |
| N::N_DTKV_2 | Snowy to NSW: transient stability limits (Yass–Bannaby–Marulan) | 2 | discharge | Out = Dapto - Kangaroo Valley (18) 330kV line, transient stability limit (Snowy-NSW) for loss of one 330kV line between Yass and Bannaby/Marulan with summated flow on 4+5+61 <=1500 |
| N>>34+5A5_33_32 | Bayswater to Liddell (33 or 34) O/L on loss of other Bayswater to | 2 | discharge | Out= Mt. Piper-Wollar (5A5) and Bayswater to Liddell (33 or 34) line, avoid O/L Bayswater to Liddell (33 or 34) 330kV line on trip of Bayswater to Sydney West (32) 330kV line, Feedback |
| N>NIL_998 | Central-west NSW: Molong–Orange North 132 kV | 1 | discharge | Out= Nil, avoid O/L Cowra to Forbes (998) on trip of Nil, Feedback |
| N>NIL_998_18 | Central-west NSW: Molong–Orange North 132 kV | 0 | discharge | Out= Nil, avoid O/L Cowra to Forbes (998) 132kV line on trip of Kangaroo Valley to Dapto (18) 330kV line, Feedback |