| V>>BELML_BAML1_BAML2 | Victoria: transient stability, Hazelwood–South Morang 500 kV | 14 | discharge | Out= Ballarat to Elaine to Moorabool 220kV line, avoid O/L Ballarat to Moorabool No.1 220kV line for trip of Ballarat to Moorabool No.2 220kV line, Feedback |
| V>>DDGN_GEDD_GNDD | North-west Victoria: voltage stability, Horsham–Murra Warra–Kiamal 220 kV | 9 | discharge | Out = Glenrowan to Dederang No.1 or No.3 220kV line, avoid O/L Goorambat East to Dederang 220kV line on loss of remaining Glenrowan to Dederang 220kV line, feedback |
| V>>NIL_MLGT_MLGT | Victoria: transient stability, Hazelwood–South Morang 500 kV | 8 | discharge | Out = NIL, avoid O/L Moorabool to Geelong #1 or #2 on trip of other Moorabool to Geelong line, Feedback |
| V>>6CGH_BEBA_ARWBBA | Victoria: transient stability, Hazelwood–South Morang 500 kV | 6 | discharge | Out= 6C, 6G, 6H 330kV lines, avoid O/L Bendigo to Ballarat 220kV line on trip of Ararat to Waubra to Ballarat 220kV line, Feedback |
| V>>NIL_ELML_BAML2 | Victoria: transient stability, Hazelwood–South Morang 500 kV | 4 | discharge | Out= Nil, avoid O/L Elaine to Moorabool 220kV line on trip of Ballarat to Moorabool No.2 220kV line, Feedback |
| V>>BAML1_ELML_BAML2 | Victoria: transient stability, Hazelwood–South Morang 500 kV | 4 | discharge | Out= Ballarat to Moorabool No.1 220kV line, avoid O/L Elaine to Moorabool 220kV line on trip of Ballarat to Moorabool No.2 220kV line, Feedback |
| V>>DDSM_BEBA_DDSM | Mount Beauty to Dederang (flow to North) for trip of the parallel | 2 | discharge | Out= Dederang to South Morang 330kV line, avoid O/L Bendigo to Ballarat 220kV line on trip of the remaining Dederang to South Morang 330kV line, Feedback |
| V>>DDSM_MBEP_DDSM | North-west Victoria: voltage stability, Horsham–Murra Warra–Kiamal 220 kV | 2 | discharge | Out= Dederang to South Morang 330 kV line, avoid O/L either Mount Beauty to Eildon 220 kV line on trip of remaining Dederang to South Morang 330 kV line, Feedback |
| V>>NIL_BEBA_ARWBBA | Victoria: transient stability, Hazelwood–South Morang 500 kV | 2 | discharge | Out= Nil, avoid O/L Bendigo to Ballarat 220kV line on trip of Ararat to Waubra to Ballarat 220kV line, Feedback |
| V>>MLTG_ELML_BAML2 | North-west Victoria: voltage stability, Horsham–Murra Warra–Kiamal 220 kV | 2 | discharge | Out= Moorabool to Terang 220kV line, avoid O/L Elaine to Moorabool 220kV line on trip of Ballarat to Moorabool No.2 220kV line, Feedback |
| V>>DDTX3_DDT2_DD1_LH | Mount Beauty to Dederang (flow to North) for trip of the parallel | 1 | discharge | Out= Dederang H3 txfmr, avoid O/L Dederang H2 220/330kV txfmr on trip of Dederang H1 220/330kV txfmr, Feedback |
| V>>6CGH_MLGT_MLGT | Victoria: transient stability, Hazelwood–South Morang 500 kV | 1 | discharge | Out = NIL, avoid O/L Moorabool to Geelong #1 or #2 on trip of other Moorabool to Geelong line, Feedback |
| CA_SYDS_59A889E5_1 | Victoria: transient stability, Hazelwood–South Morang 500 kV | 0 | discharge | Constraint Automation, O/L BATS_MLTS2_220:LML2:I:220@BATS@VIC for CTG LVAK on trip of MLTS-TGTS 220KV LINE. Generated by STNET[NORCR4] Host NORREGEEMP8(EMPSYD) |
| V>>BELMLCB_BAML_TGML | Victoria: transient stability, Hazelwood–South Morang 500 kV | 0 | discharge | Out= Ballarat to Elaine to Moorabool 220kV line and Moorabool to Ballarat No.1 line No.1 bus CB at Moorabool, avoid O/L Ballarat to Moorabool No.2 220kV line on trip of Terang to Moorabool 220kV line offloading Ballarat to Moorabool No.1 line, Feedback |
| V>>SMF2_SMF1_NIL_R5 | The remaining South Morang 500/ F transformer | 0 | charge | Out = South Morang 500/330kV F2 transformer, avoid pre-contingent O/L of the remaining South Morang F1 500/330kV transformer, radial mode, YWPS unit 1 on 500kV, feedback |