| V^^N_CNCW_1 | Out = Canberra-Capital (6) or Kangaroo Valley to Capital (3W), avoid | 171 | charge | Out = Canberra-Capital (6) or Kangaroo Valley to Capital (3W), avoid voltage collapse around Murray for loss of all APD potlines |
| N::N_CNCW_2 | Snowy to NSW: transient stability limits (Yass–Bannaby–Marulan) | 145 | discharge | Out = Canberra-Capital (6) line, stability limit (Snowy-NSW) for critical fault of one 330kV line between Yass and Bannaby/Marulan |
| N::N_SDUT_2 | Snowy to NSW: transient stability limits (Yass–Bannaby–Marulan) | 111 | discharge | Out = Upper Tumut-Stockdill (1) 330kV line, stability limit (Snowy-NSW) for fault of various location between Yass-South Morang area |
| V>>N_NIL_65_051 | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 34 | discharge | Out = NIL, avoid O/L Murray to Upper Tumut (65) on trip of Wagga to Lower Tumut (051) line, Feedback |
| V^^N_NIL_1 | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 33 | charge | Out = Nil, avoid voltage collapse around Murray for loss of all APD potlines |
| V^^N_SDUT_1 | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 11 | charge | Out = Stockdill to Upper Tumut (1) line, avoid voltage collapse around Murray for loss of all APD potlines |
| V^^N_BADP_1 | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 10 | charge | Out = Balranald to Darlington Point (X5) 220kV line, avoid voltage collapse around Murray for loss of all APD potlines |
| V^^N_GRYS_1 | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 7 | charge | Out = Gullen Range to Yass (3J), avoid voltage collapse around Murray for loss of all APD potlines |
| CA_BRIS_59B1EA1C_1 | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 5 | discharge | Constraint Automation, O/L 65:LSM1:I:330@MURRAY@VIC for CTG LHPA on trip of LTSS-MSS (66) 330KV LINE. Generated by STNET[NORCR1] Host BNEREGEEMP5(EMPBRI) |
| V>>N_051+X5_65_66 | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 5 | discharge | Out = Lower Tumut to Wagga (051) 330kV line, avoid O/L Murray to Upper Tumut (65) 330kV line on trip of Murray to Lower Tumut (66) 330kV line, Wagga to Yass 132kV network split, X5 or 63 opened, 9R4 opened and 2 Yass transformers in service, Feedback |
| N::N_GRRP_2 | Snowy to NSW: transient stability limits (Yass–Bannaby–Marulan) | 4 | discharge | Out = Gullen Range to Rye Park (3P), stability limit (Snowy-NSW) for loss of Yass-Marulan (4/5) 330kV line |
| V^^N_BADP_DTKV_1 | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 3 | charge | Out = Balranald to Darlington Point (X5) 220kV line and Dapto - Kangaroo Valley (18) 330kV line, avoid voltage collapse around Murray for loss of all APD potlines |
| N::N_DTKV_2 | Snowy to NSW: transient stability limits (Yass–Bannaby–Marulan) | 2 | discharge | Out = Dapto - Kangaroo Valley (18) 330kV line, transient stability limit (Snowy-NSW) for loss of one 330kV line between Yass and Bannaby/Marulan with summated flow on 4+5+61 <=1500 |
| V^^N_DTMN_1 | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 0 | charge | Out = Dapto to Marulan (8) 330kV Line, avoid voltage collapse around Murray for loss of all APD potlines |
| N>>V_6CGH_65_66 | Southern NSW: Jindera–Wodonga and Wagga–Lower Tumut 330 kV | 0 | charge | Out = 6C, 6G, 6H 330kV lines, avoid Upper Tumut to Murray(65) using 15 mins rating O/L on Lower Tumut to Murray(66) trip; (Note: constraint is swamped out if TL 64 is O/S) |