| S>>BWMP_TWPA_TPRS | Manage voltage collapse in northern SA for the trip of one 275kV line | 42 | discharge | Out= Blyth West- Munno Para 275kV line with Blyth West CB8002 OPEN, avoid O/L Templers-Roseworthy 132kV line on trip of Templers West-Para 275kV line, Feedback |
| S>NIL_HUWT_STBG | Snowtown - Bungama on loss of Hummocks - Waterloo | 40 | discharge | Out = Nil; avoid O/L on Snowtown - Bungama line 132kV on loss of Hummocks - Waterloo 132kV line, Feedback |
| S^NIL_SA_NORTH | Manage voltage collapse in northern SA for the trip of one 275kV line | 24 | discharge | Out = NIL, Manage voltage collapse in northern SA for the trip of one 275kV line between Davenport-Para or Davenport-Tungkillo.(Note: for both DV + RB Syn Cons are I/S, OR one DV Syn Con O/S, OR one RB Syn Con O/S, OR one DV +RB Syn Con O/S) |
| S>>NIL_TWPA_TPRS | Manage voltage collapse in northern SA for the trip of one 275kV line | 16 | discharge | Out= NIL, avoid O/L Templers-Roseworthy 132kV line on trip of Templers West-Para 275kV line, Feedback |
| S>NIL_BWMP_RHBR-T | Redhill-Brinkworth T | 10 | discharge | Out= Nil, avoid O/L Redhill-Brinkworth T 132kV line on trip of Blyth West-Munno Para 275kV line, Feedback |
| S-NIL_WTPT_SC+INV_1 | Limit output of Wattle Pt WF based on Wattle Pt statcom status & the | 9 | discharge | Out=NIL, limit output of Wattle Pt WF based on Wattle Pt statcom status & the number of Dalrymble battery inverters I/S (Note: constraint is swamped when the number of Dalrymple battery inverters is less than 10) |
| S-NIL_WTPT_SC+INV_2 | Limit output of Wattle Pt WF based on Wattle Pt statcom status & the | 8 | discharge | Out=NIL, limit output of Wattle Pt WF based on Wattle Pt statcom status & the number of Dalrymble battery inverters I/S (Note: constraint is swamped when the number of Dalrymple battery inverters is >= 10) |
| S^WPWF_60 | Limit output of Wattle Pt WF based on Wattle Pt statcom status & the | 6 | discharge | Out = Brinkworth-Redhill 132kV line (Redhill-Bungama section in service), Brinkworth-Redhill-Bungama line, Hummocks-Waterloo line or Bungama 275/132kV TX; limit Wattle Pt WF to 60MW to avoid voltage collapse on trip of Bungama TX or Hummocks-Waterloo line |
| S>>BWMP_DVBR_RHBG-T | Manage voltage collapse in northern SA for the trip of one 275kV line | 3 | discharge | Out= Blyth West- Munno Para 275kV line with Blyth West CB8002 OPEN, avoid O/L Redhill- Brinkworth 132kV T line on trip of Davenport-Brinkworth 275kV line, Feedback |
| S>>BWMP_BRTW_WTTP | Manage voltage collapse in northern SA for the trip of one 275kV line | 3 | discharge | Out= Blyth West- Munno Para 275kV line with Blyth West CB8002 OPEN, avoid O/L Waterloo-Templers 132kV line on trip of Brinkworth-Templers West 275kV line, Feedback |
| S>>BWMP_HUWT_RHBG-T | Manage voltage collapse in northern SA for the trip of one 275kV line | 3 | discharge | Out= Blyth West- Munno Para 275kV line with Blyth West CB8002 OPEN, avoid O/L Redhill-Brinkworth 132kV T line on trip of Hummocks-Waterloo 132kV line, Feedback |
| S>>BRTW_BWPA_WTTP | Manage voltage collapse in northern SA for the trip of one 275kV line | 3 | discharge | Out= Brinkworth- Templers West 275kV line, avoid O/L Waterloo-Templers 132kV on trip of Blyth West-Munno Para 275kV line, Feedback |
| S>>NIL_RBTU_WEWT | Waterloo East-Waterloo | 2 | charge | Out= Nil, avoid O/L Waterloo East-Waterloo 132kV line on trip of one Robertstown-Tungkillo 275kV line, Feedback |
| S_WP_ISL | Limit output of Wattle Pt WF based on Wattle Pt statcom status & the | 2 | discharge | Out= Yorke Peninsula 132kV network islanded (i.e. island formed between Hummocks-Androssan West- Dalrymple 132kV network), Wattle Pt WF islanded |
| S>>NIL_BWMP_WTTP | Manage voltage collapse in northern SA for the trip of one 275kV line | 2 | discharge | Out= Nil, avoid O/L Waterloo - Templers 132kV on trip of Blyth West- Munno Para 275kV line, Feedback |